Aksesorë
Separation Tube
|
UTP-AX054A Gas Pipe |
UTP-AX090A Gas Pipe |
UTP-AX180A Gas Pipe |
UTP-AX567A Gas Pipe |
| Model name | UTP-AX054A | UTP-AX090A | UTP-AX180A | UTP-AX567A |
|---|---|---|---|---|
| Total cooling capacity of indoor unit | 19.6kW or less | 28.0kW or less | 28.1kW to 56.0kW | 56.1kW or more |
|
UTP-BX090A Suction Gas Pipe |
UTP-BX180A Suction Gas Pipe |
UTP-BX567A Suction Gas Pipe |
| Model name | UTP-BX090A | UTP-BX180A | UTP-BX567A |
|---|---|---|---|
| Total cooling capacity of indoor unit | 28.0kW or less | 28.1kW to 56.0kW | 56.1kW or more |
Header
|
UTR-H0906L Gas Pipe |
UTR-H0908L Gas Pipe |
UTP-J0906A Suction Gas Pipe |
UTP-J0908A Suction Gas Pipe |
| Model name | 3-6 Branches | UTR-H0906L UTP-J0906A |
UTR-H1806L UTP-J1806A |
|---|---|---|---|
| 3-8 Branches | UTR-H0908L UTP-J0908A |
UTR-H1808L UTP-J1808A |
|
| Total cooling capacity of indoor unit | 28.0kW or less | 28.1kW to 56.0kW | |
Outdoor Unit Branch Kit
|
UTP-CX567A Gas Pipe |
UTP-DX567A Suction Gas Pipe |
| Model name | UTP-CX567A (for V-II) | UTP-DX567A (for VR-II) | |
|---|---|---|---|
| Number of Outdoor unit | 2 outdoor units | 1 | |
| 3 outdoor units | 2 | ||
EV Kit
|
For Compact Wall Mounted type
|
| Model name | UTR-EV09XB | UTR-EV14XB |
|---|---|---|
| Application Model | ASYE04GACH ASYE07GACH ASYE09GACH |
ASYE12GACH ASYE14GACH |
RB Unit
|
Single type
|
Multi type
|
| Type | Single type | Multi type | ||
|---|---|---|---|---|
| Model name | UTP-RX01AH | UTP-RX01BH | UTP-RX01CH | UTP-RX04BH |
| Power source | Single phase 230V, 50Hz | |||
| Input power | 17W | 24W | 31W | 96W |
| Number of branches | 1 | 1 | 1 | 4 |
| Maximum capacity of connectable indoor units(Q) | Q ≤ 8.0kW | Q ≤ 18.0kW | Q ≤ 28.0kW | Q ≤ 56.0kW *1 |
| Maximum capacity of connectable indoor units per branch(Q) | Q ≤ 8.0kW | Q ≤ 18.0kW | Q ≤ 28.0kW | Q ≤ 18.0kW |
| Maximum number of connectable indoor units per branch | 3 | 8 | 8 | 8 |
| Dimensions | 198(H) × 298(W) × 268(D)mm | 260(H) × 658(W) × 428(D)mm | ||
*1 : In case of two RB units connected in series ( total 8-branches ), maximum capacity of connectable indoor units is up to 56.0kW.
Controllers
For Individual Control
|
Wired Remote Controller(Touch Panel ) UTY-RNRY
|
Wired Remote Controller UTY-RLRY
|
Simple Remote Controller UTY-RSKY
|
Simple Remote Controller UTY-RHKY
|
|
Wireless Remote Controller UTY-LNHY
|
IR Receiver Unit UTB-YWC
|
IR Receiver Unit UTY-LRHYB1
|
For Centralized Control
|
Group Remote Controller UTY-CGGY
|
Central Remote Controller UTY-DCGY
|
Touch Panel Controller UTY-DTGY
|
System Controller Lite(Software) UTY-ALGX
|
|
System Controller(Software) UTY-APGX
|
Convertors / Adaptors
For External device
|
BACnet®Gateway(Software) UTY-ABGX
|
Network Convertor UTY-VLGX
|
KNX® Interface FJ-RC-KNX-1i
|
|
MODBUS® Interface FJ-RC-MBS-1
|
Wireless LAN Interface FJ-RC-WIFI-1
|
External Switch Controller UTY-TEKX
|
For System expansion
|
Network Convertor UTY-VGGXZ1
|
Signal Amplifier UTY-VSGXZ1
|
Panels
For Cassette type
|
Cassette Grille UTG-UFYC-W For Compact Cassette type
|
Cassette Grille UTG-UGYA-W For Cassette type
|
Others
Communication system: External Connect Kit
|
For Indoor unit UTY-XWZXZ7
UTY-XWZXZB
UTY-XWZXZC
UTY-XWZXZD
UTY-XWZXZE
|
For Outdoor unit UTY-XWZXZ6
UTY-XWZXZ9
|
|
|
For RB unit UTY-XWZXZ6
UTY-XWZXZB
|
For Central Remote Controller UTY-XWZXZ7
UTY-XWZXZ8
UTY-XWZXZA
|
For Touch Panel Controller UTY-XWZXZA
|
Function list
| Indoor unit | Outdoor unit | Controller | Other | |||
| Central Remote Controller | Touch Panel Controller | RB Unit | ||||
| Input | Operation / Stop | |||||
| All On / All Off | ||||||
| Batch Stop | ||||||
| Forced Stop | ||||||
| Emergency Stop | ||||||
| Forced Thermostat off | ||||||
| Low Noise Mode Operation | ||||||
| Cooling / Heating Priority | ||||||
| "Outdoor Unit Operation Peak Control" | ||||||
| "Power Usage Information from Electricity Meter" | ||||||
| Output | Operation Status | |||||
| Error Status | ||||||
| Indoor Unit Fun Operation Status | ||||||
| Auxiliary Heater Output | ||||||
| Base Heater | ||||||
*1 : Heat Pump type only *2 : Duct type only.
: Dry Contact
: Apply Voltage
For Duct typet
|
Flange (Round) UTD-RF204 For Medium Static Pressure Duct type
|
Flange (Square) UTD-SF045T For Medium Static Pressure Duct type
|
Remote Sensor Unit UTY-XSZX For All Duct type
New amenity space can be offered by installing the Remote sensor. |
|
Long-Life Filter UTD-LF25NA For Medium Static Pressure Duct type
UTD-LF60KA For High Static Pressure Duct type (ARXC36/45/60GATH)
|
Auto Louver Grille Kit UTD-GXSA-W For Slim Duct type
|
Drain Pump Unit UTZ-PX1BBA For Low Static Pressure Duct type UTZ-PX1NBA For Medium Static Pressure Duct type
|
For Cassette type
|
Wide Panel UTG-AGYA-W For Cassette type
|
Panel Spacer UTG-BGYA-W For Cassette type
|
Insulation Kit for High Humidity UTZ-KXGA For Cassette type
|
|
Fresh Air Intake Kit UTZ-VXAA For Compact Cassette type
UTZ-VXGA For Cassette type
|
Air Outlet Shutter Plate UTR-YDZB For Compact Cassette type
Shuts the air outlet when only using as 3 blow out. |
Air Outlet Shutter Plate UTR-YDZC For Cassette type
Shuts the air outlet when only using as 3 blow out. |
For Ceiling type
|
Drain Pump Unit UTR-DPB24T For Ceiling type
|